|
PERMIT NO: R11-0249
|
E-PERMIT
|
|
|
CITY OF SANTA CRUZ
877 Cedar Street, Suite 100, CA 95060
|
INSPECTION REQUEST LINE
(831) 420-5120
OR
To SCHEDULE INSPECTION
ON-LINE
Permits Online
|
|
PERMIT TYPE
BLDG RESIDENTIAL
|
PERMIT SUB-TYPE
ROOFING
|
JOB VALUE 8200
|
APN 004-251-11
|
DESCRIPTION
re-roof w/ comp. shingle
|
|
|
APPLIED DATE
10/24/2011
|
|
APPROVED DATE
10/24/2011
|
|
ISSUED DATE
10/24/2011
|
|
|
|
PERMIT INFORMATION
|
FEE SUMMARY
|
|
SITE
|
724 COLUMBIA ST SANTA CRUZ, CA 95060-6012
|
|
|
APPLICANT
|
adrain porca
724 columbia st SANTA CRUZ CA 95060
|
|
|
OWNER
|
STRICKLAND MATT T U/M
SACRAMENTO CA 95819
|
|
|
CONTRACTOR
|
ROY HORN CONSTRUCTION
803 RIVERVIEW DR CAPITOLA CA 95010
|
|
|
| BUILDING PERMIT FEES | $0.82 |
| BUILDING PERMIT FEES | $1.00 |
| MISCELLANEOUS BUILDING FEES | $8.36 |
| BUILDING DEPOSIT | $0.00 |
| BUILDING PERMIT FEES | $167.25 |
| MISCELLANEOUS BUILDING FEES | $3.00 |
| Total Fees Collected: | $180.43 |
|
|
|
NOTE: This job copy of this permit shall be kept on the job site to make the required entries thereon.
The permit will expire if work is abandonded or does not pass an inspection for more than 180 days from issuance or last
passed inspection. Additional fees will be collected to renew expired permits. This is a Building Permit when properly filled out, signed and validated, and is not transferable. Construction noise is subject to SCMC Section 9.36.010 including no construction noise prior to 8:00 AM.
|
|
|
|
|
|
|
All work must comply with current and applicable state and local codes.
- Solar Panels: When solar panels are present on a roof a licensed electrician must concurrently apply for a separate electrical permit for the reinstallation of solar equipment for reroofing projects.
- Underlayment: Underlayment shall comply with CRC R905.1.1 and manufacturer’s specifications which shall be kept on site for inspector verification.
- Cricket or Saddle (per CRC R903.2.2): Cricket or saddle shall be installed on the ridge side of any chimney or penetration more than 30 inches wide as measured perpendicular to the slope.
- Roof Slope Requirements:
- Wood Shake & Shingle Roofs (per CRC R905.7.2 & R905.8.2): Less than 3:12 – Wood shake & wood shingles may not be used.
- Asphalt Roofs (per CRC R905.2.2): Less than 2:12 – Asphalt shingles may not be used. Greater than or equal to 2:12 – Asphalt shingles may be used. 2:12 – 4:12 – Asphalt shingles may be used and require double underlayment.
- Built-Up Roofs (per CRC R905.9.1): Greater than or equal to 1/4:12 Built-up roofs may be used. Greater than or equal to 1/8:12 Coal-tar built-up roofs may be used.
- Spark Arrester (per CRC R1003.9.2): All chimneys attached to any appliance or fireplace that burns solid fuel shall be equipped with an approved spark arrester.
- Engineering Calculations: If new plus existing roof weighs more than 6 psf, engineering calculations or verification of compliance with the UBC span tables is required.
- Fire Rating (per Municipal Code 18.04): All wood shake and shingle roofs installed in the State of California must be approved by the State Fire Marshal. In the City of Santa Cruz, all roofs must be at least Class B rated.
- Contractor’s License & Workman’s Compensation: Through this ePermit process you have affirmed under penalty of perjury that you are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the business and Professions Code, and your license is in full force and effect. Additionally you have attested that you have and will maintain workman’s compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which the permit is issued.
|
|
|
Roofer's Self Certification for Licensed C39 Roofing Contractors
|
I hereby affirm under penalty of perjury, that I or my employees have made the following corrections or performed the following installation in reroofing for this permit.
Sheathing type & thickness: ______________ Species: _______________ Grade: _______________ Panel strand index: _____________
Nailing on edge: ____________ Nailing in field: ____________ Sheet metal reused: _____________ Sheet metal replaced: ____________
|
Contractor: Name ________________________________ Signature ___________________________________ Date _____________
|
|
|
Affidavit for Smoke & Carbon Monoxide Alarm(s) Self Certification
|
For compliance with CRC R314 & R315, CBC 907.2.11.2-9 this affidavit must be filled out and signed by the owner and contractor after installation and prior to the final inspection.
Go to Permits Online for Smoke and CO Affidavit Instructions and Requirements.
Number of Alarms Installed: Smoke ____ Carbon Monoxide _____
Owner: Name ___________________________________ Signature ___________________________________ Date _____________
Contractor: Name ________________________________ Signature ___________________________________ Date _____________
|
|
|
|
|
INSPECTION SUMMARY
|
| ______ R-TEAROFF |
| ______ R-IN PROGRESS |
| ______ R-ROOF FINAL |
|
|
|
|
Permit Finaled Date: __________
Inspector Name: __________________ Signature: __________________
|